Related Experiment Video
Updated: Aug 13, 2026

Synchrotron X-ray Microdiffraction and Fluorescence Imaging of Mineral and Rock Samples
Published on: June 19, 2018
Patella lead x-ray fluorescence measurements are independent of sample orientation
A C Todd1, J H Godbold, E L Moshier
1The Mount Sinai School of Medicine, Department of Community and Preventive Medicine, New York, New York 10029, USA. andrew.todd@mssm.edu
Abstract:
In vivo x-ray fluorescence bone lead measurements assess long-term lead exposure. Tibia, calcaneus, and patella are the most commonly sampled bones. Patella measurements also include lead signals from the distal femur, proximal tibia, and synovium. It is therefore important to know whether the orientation of the patella relative to the measurement system substantially affects the measured patella lead concentrations and their measurement uncertainties. This study examined whether these parameters exhibited a dependence on the orientation of the patella with respect to the measurement system, a dependence that could arise from varying nonpatella contributions. There was no effect of orientation on measured patella lead concentration, but there was a highly significant effect of orientation on the measurement uncertainty. These data do not conclusively show that there are no nonpatella contributions to a patella lead measurement; rather, that any such contributions are not a function of measurement orientation over the range of orientations considered. Further study is required if the contribution of nonpatella tissues to a patella lead XRF-measured concentration is to be fully addressed. This study also filled a gap in the literature by quantifying the within-patella (29%) and between-patella (71%) variability of measured patella lead concentrations from replicate measures of nine patellae.
More Related Videos
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
05:54Polarization-Sensitive Two-Photon Microscopy for a Label-Free Amyloid Structural Characterization
Published on: September 8, 2023
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Photoluminescence: Applications
Flame Photometry: Lab
Determination of Crystal Structures