Air sampling at the chest and ear as representative of the breathing zone
S E Guffey1, M E Flanagan, G van Belle
1IMSE Department, West Virginia University, Morgantown 26506-6070, USA.
Abstract:
Tracer gas concentrations were measured on a 60%-sized mannequin holding a pure sulfur hexafluoride source in its hands at waist height while it stood in a wind tunnel. Samplers were placed at the mannequin's mouth, in front of the ear, and at three chest locations at lapel level. Simultaneous 15-min time-weighted average samples were taken by drawing air into different sampling bags with sampling pumps. For the factorial study design, test conditions included cross-draft velocities of 10, 22, 47, and 80 ft/min; three mannequin orientations (facing to, side to, and back to cross-draft), and rotating speed through an 80 degrees arc (fast, slow, and no movement). Each study condition was tested twice. Concentrations at all sampling locations when the mannequin faced to the front and side were less than a tenth of the levels measured at the nose (Cnose) when the mannequin faced downstream. Higher velocities significantly increased concentration at the Back orientation and generally reduced it at the Side and Facing orientations. Concentrations at the nose were different from concentrations at other sites. For 34 of 36 samples the mean chest concentration (Cchest,) was higher than the Cnose (geometric mean three times higher). The ratio of ear (Cear) and Cnose varied with orientation. At the Back orientation, Cear, was lower than Cnose, whereas Cear was higher than Cnose at the Side and Facing to flow orientations. Velocity affected the ratios of concentrations. At the Back orientation, the chest sampler provided lower overestimates of Cnose, at higher velocities than at lower values. Mannequin movement, done only at the Back orientation, proved important only for the ear location. Results showed significant and substantial differences between concentrations at the nose and lapel. However, these findings should be interpreted with caution because a very dense tracer gas and an unheated, nonbreathing mannequin were used. In more realistic conditions, the findings probably would show far smaller differences in concentrations at different sampling sites.
Related Concept Videos
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract I: Health History
Subjective Data
Subjective data provides vital information about the patient's health history and symptoms. This data is typically collected through interviews in which patients describe their experiences, symptoms, and concerns.
Health history and key...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.