[The measurement of blood volume--state-of-the-art]

V H Orth1, M Rehm, M Haller

  • 1Klinik für Anästhesiologie, Klinikum Grosshadern, Ludwig-Maximilians-Universität München. vorth@ana.med.uni-muenchen.de

Der Anaesthesist
|September 15, 2001
PubMed

The term blood volume (BV) measurement can be understood as the exact volumetric definition of both components of blood, the red cell volume (RCV) and the plasma volume (PV) using tracer dilution methods. The tracer used to measure the RCV must be bound to the erythrocytes and for the PV to plasma proteins, in order to label the distribution space of each carrier (i.e. erythrocytes and albumin molecules). To differentiate this there are indirect methods to estimate the BV, such as measurement of the diastolic pressure or transoesophageal echocardiography, which will not be discussed here. Alterations in the RCV and PV cannot be routinely measured, or at most only roughly estimated by means of the haematocrit (Hc) or haemoglobin (Hb) concentration which can lead to serious errors when large changes have occurred. At present measurements of the RCV and PV are not carried out in routine clinical practice. The introduction of nonradioactive tracers with a faster elimination now renders possible a relatively exact measurement of both volumes under certain clinical situations, albeit with a high technical outlay. The RCV is measured using the tracer sodium fluorescein (SoF) and the PV with the dye indocyanine green (ICG). The RCV measurement seems to be suitable for certain clinical situations, such as characterization of the preoperative condition of a patient or quantification of surgical blood loss after an operation, because it is less invasive and has a high precision. However, the results of the RCV measurement can only be delivered after 1 h which makes it more suitable for clinically stable situations. In contrast the PV estimation is based on the measurement of the ICG concentration in the arterial bloodstream after a bolus injection of the dye in the central veins and is used more in intensive care because of the invasivity. The results can be obtained 5 min after injection of the dye and therefore even rapid changes in the PV can be monitored.

Related Concept Videos

Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure01:28

Special considerations while measuring blood pressure

When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure01:17

Measurement of Blood Pressure

Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a stethoscope.