Non-invasive cardiac output evaluation during a maximal progressive exercise test, using a new impedance cardiograph
R Richard1, E Lonsdorfer-Wolf, A Charloux
1Service des Explorations Fonctionnelles Respiratoires, Cardio-Circulatories et de l'Exercice, Hôpitaux Universitaires de Strasbourg, Hôpital Civil, BP 426, 67091 Strasbourg, France. ruddy.richard@physio-ulp.u-strasbg.fr
Abstract:
One of the greatest challenges in exercise physiology is to develop a valid, reliable, non-invasive and affordable measurement of cardiac output (CO). The purpose of this study was to evaluate the reproducibility and accuracy of a new impedance cardiograph device, the Physio Flow, during a 1-min step incremental exercise test from rest to maximal peak effort. A group of 12 subjects was evaluated to determine the reproducibility of the method as follows: (1) each subject performed two comparable tests while their CO was measured by impedance cardiography using the new device (COImp1, COImp2), and (2) in a subgroup of 7 subjects CO was also determined by the direct Fick method (COFick) during the second test. The mean difference between the values obtained by impedance (i.e. COImp1-COImp2) was -0.009 l.min-1 (95% confidence interval: -4.2 l.min-1, 4.2 l.min-1), and CO ranged from 3.55 l.min-1 to 26.75 l.min-1 (n = 146). When expressed as a percentage, the difference (COImp1-COImp2) did not vary with increasing CO. The correlation coefficient between the values of COImp and COFick obtained during the second exercise test was r = 0.94 (P < 0.01, n = 50). The mean difference expressed as percentage was -2.78% (95% confidence interval: -27.44%, 21.78%). We conclude that COImp provides a clinically acceptable evaluation of CO in healthy subjects during an incremental exercise.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes