Analyzing and correcting spectrometer temperature sensitivity
P J Bowyer1, A G Swanson, G A Morris
1Department of Chemistry, University of Manchester, Oxford Road, Manchester M13 9PL, United Kingdom.
Abstract:
Stability and reproducibility of the spectrometer are fundamental to the success of many modern NMR experiments. Variation in room temperature is a particularly important source of instability, in part because it can cause coherent artifacts in NMR spectra. Small changes in room temperature lead to corresponding changes in the phases, amplitudes, and frequencies of NMR signals. These can lead in turn to apparently random spectral artifacts such as t(1)-noise in two-dimensional (2D) NMR and to the incomplete cancellation of signals in difference spectra, but also, importantly, to F(1) satellite signals in 2D spectra. These "parallel diagonals" arise from the use of air conditioning, which typically forces room temperature to oscillate within a fixed band. Work to identify, quantify, and suppress sources of temperature sensitivity in a modern 300-MHz spectrometer has led to a greater than 10-fold improvement in the signal-to-artifact ratio.
More Related Videos
09:18Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
09:40Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
Related Concept Videos
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature from...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
UV–Vis Spectrometers
IR Spectrometers
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...