Multi-detector row CT angiography of lower extremity arterial inflow and runoff: initial experience
G D Rubin1, A J Schmidt, L J Logan
1Department of Radiology, Stanford University School of Medicine, 300 Pasteur Dr, Rm S-072B, Stanford, CA 94305-5105, USA. grubin@stanford.edu
Purpose:
To assess the patterns of lower extremity arterial inflow and runoff opacification with four-channel multi-detector row computed tomographic (CT) angiography in a cohort of patients with disease warranting imaging of the lower extremity arterial system.
Materials And Methods:
Twenty-four patients with symptomatic lower extremity arterial occlusive or aneurysmal disease underwent imaging with four-channel multi-detector row CT from the supraceliac abdominal aorta through the feet. Transverse sections were acquired with a 2.5-mm nominal detector width and pitch of 6.0 (3.2-mm effective section thickness) following intravenous injection of 174-185 mL of iodinated contrast medium (300 mg iodine per milliliter). In each patient, attenuation measurements were recorded in 16 arterial and 16 venous locations. In 18 patients, two radiologists assessed the detectability and stenosis degree of 21 arterial segments per patient relative to these features at conventional angiography.
Results:
A mean scanning time of 66 seconds was required to cover a mean of 1,233 mm, resulting in a mean of 908 transverse reconstructions. All 504 arterial segments were depicted and analyzable. Mean arterial attenuation ranged from 253 HU in the midabdominal aorta to 357 HU in the popliteal artery and 253 HU in the dorsalis pedis or posterior tibial artery measured inferior to the tibiotalar joint. Maximum mean venous enhancement (99 HU) was observed in the saphenous vein at the ankle, with all other venous stations measuring less than 74 HU.
Conclusion:
The arteries of lower extremity inflow and runoff can be reliably depicted with minimal venous enhancement by using multi-detector row CT.
More Related Videos
04:35Sample Preparation for Computed Tomography-based Three-dimensional Visualization of Murine Hind-limb Vessels
Published on: October 7, 2021
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging