Related Experiment Video
Updated: Jul 27, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Spiral versus electron-beam CT for coronary artery calcium scoring
J G Goldin1, H C Yoon, L E Greaser
1Department of Radiological Sciences, UCLA School of Medicine, 10833 Le Conte Ave, CHS B2-200, Los Angeles, CA 90095-1721, USA. jgoldin@mednet.ucla.edu
Purpose:
To determine differences in coronary artery calcium detection, quantification, and reproducibility, as measured at electron-beam computed tomography (CT) and subsecond spiral CT with retrospective electrocardiogram gating in an asymptomatic adult population.
Materials And Methods:
Seventy subjects asymptomatic for coronary heart disease underwent both electron-beam CT and subsecond spiral CT. In all subjects, two images each were obtained with both scanners. Two experienced readers using three different algorithms scored each of the four scans: one score for the electron-beam CT images and two scores for the spiral CT images.
Results:
With a 130-HU threshold for the quantification of calcium, there were no significant differences in interscan and interobserver variation in calcium scores between the electron-beam CT and spiral CT images. There was greater interobserver (P <.001) and interscan (P <.03) variation in scores when a 90-HU threshold was used for spiral CT images. With a 130-HU threshold, when calcium scores were used for clinical risk stratification, there was a significant difference between the results obtained with electron-beam CT and those obtained with spiral CT (P <.05).
Conclusion:
Spiral CT has not yet proved to be a feasible alternative to electron-beam CT for coronary artery calcium quantification. There are systematic differences between calcium scores obtained with single-detector array subsecond spiral CT and those obtained with electron-beam CT.
More Related Videos
06:57Semi-Automatic Graphical Tool for Measuring Coronary Artery Spatially Weighted Calcium Score from Gated Cardiac Computed Tomography Images
Published on: September 22, 2023
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Acute Coronary Syndrome III: Diagnostic Studies