Related Experiment Video
Updated: Oct 4, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Fluorodeoxyglucose positron emission tomography for detection of recurrent or metastatic breast cancer
1Department of Surgery, Seoul National University, College of Medicine, 28 Yongon-Dong, Chongno-Gu, Seoul 110-744, Korea.
Abstract:
Fluorodeoxyglucose-positron emission tomography (FDG-PET) is a noninvasive imaging technique capable of identifying primary tumors and metastases with high sensitivity and accuracy. The aim of this study was to evaluate the diagnostic accuracy of whole-body FDG-PET imaging for the detection of recurrent or metastatic breast cancer after surgery. Whole-body FDG-PET imaging was performed on 27 patients with suspected recurrent breast carcinoma. PET images were evaluated qualitatively for each patient and lesion. FDG-PET scans showed that there were 61 reference sites of malignant or benign lesions in 27 patients. In a patient-based analysis, FDG-PET scans correctly identified 16 of 17 patients with recurrent or metastatic disease and 8 of 10 without recurrence, resulting in a sensitivity, specificity, and accuracy of 94%, 80%, and 89%, respectively. In a lesion-based analysis, FDG-PET scans correctly identified 46 of 48 lesion sites with recurrent or metastatic disease and 11 of 13 without recurrence. The overall sensitivity, specificity, and accuracy for all lesion sites were 96%, 85%, and 93%, respectively. FDG-PET scans revealed unsuspected recurrent or metastatic diseases in 8 of 27 (30%) of patients and 11 of 20 (55%) distant metastatic lesions. In 13 patients treatment was altered by the outcome of the PET scan. We concluded that whole-body FDG-PET scan is a useful diagnostic imaging modality for detecting recurrent or metastatic breast carcinoma in patients suspected of having recurrent disease after primary surgery.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
