Related Experiment Video
Updated: Sep 2, 2026

Patch-clamp Capacitance Measurements and Ca2+ Imaging at Single Nerve Terminals in Retinal Slices
Published on: January 19, 2012
Direct observation of membrane retrieval in chromaffin cells by capacitance measurements
A W Henkel1, H Horstmann, M K Henkel
1Department of Psychiatry (Molecular Neurobiology), University of Erlangen, Germany. andreas.henkel@psych.imed.uni-erlangen.de
Abstract:
This study was focussed on the identification of the endocytic organelles in chromaffin cells which retrieve large, dense core vesicle (LDCV)-membrane components from the plasma membrane. For this purpose, 'on-cell' capacitance measurements and electron microscopy were employed. We found capacitance steps and capacitance flickers, corresponding to single exo- and endocytic events. The analysis revealed that the total membrane surface of completely fused LDCVs is recycled by large endocytic vesicles and smaller, most likely clathrin-coated vesicles, at approximately the same ratio. These results were confirmed by rapid-freeze immuno-electron microscopy, where an extracellular marker was rapidly internalized into endocytic vesicles that morphologically resembled LDCVs.