Direct measurement of the Josephson supercurrent in an ultrasmall Josephson junction

A Steinbach1, P Joyez, A Cottet

  • 1Service de Physique de l'Etat Condensé, CEA-Saclay, F-91191 Gif-sur-Yvette, France.

Physical Review Letters
|October 3, 2001
PubMed

Related Concept Videos

Magnetic Force Between Two Parallel Currents01:13

Magnetic Force Between Two Parallel Currents

Two long, straight, and parallel current-carrying conductors exert a force of equal magnitude on one another. The direction of the force depends on the current direction in the conductors.
The force exerted by the magnetic field due to the first conductor over a finite length of the second conductor is given as the product of the current in the second conductor and  the vector product of the length vector along the current element and the field due to the first conductor. According to the...
Magnetic Field Of A Current Loop01:16

Magnetic Field Of A Current Loop

Consider a circular loop with a radius a, that carries a current I. The magnetic field due to the current at an arbitrary point P along the axis of the loop can be calculated using the Biot-Savart law.
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential ensures...
Controlled-Current Coulometry: Coulometric Titration01:18

Controlled-Current Coulometry: Coulometric Titration

Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
Junction Potentials in Galvanic Cells01:21

Junction Potentials in Galvanic Cells

The Nernst equation, derived under the assumption of thermodynamic equilibrium, calculates the electromotive force (emf) as the sum of potential differences at phase boundaries in a reversible cell without a liquid junction. However, in irreversible cells such as the Daniell cell, an additional potential difference named the liquid-junction potential (EJ) arises across the interface of two electrolyte solutions due to different ion diffusion rates. This EJ represents the potential difference...