Nitrate determination in baby food, using the nitrate ion selective electrode
Related Experiment Video
Updated: Nov 3, 2026

Measuring Nitrite and Nitrate, Metabolites in the Nitric Oxide Pathway, in Biological Materials using the Chemiluminescence Method
Published on: December 25, 2016
Abstract:
The nitrate electrode has been utilized in the determination of nitrate content in food products. The AOAC xylenol method was employed for comparative results. A reasonable correlation (r=0.91) was found between the 2 methods in the analysis of 49 samples containing 30-350 ppm nitrate. At the average nitrate content (100 ppm) of these foods, the standard error was 4.3 ppm. The electrode responds directly to the ionic activity of the nitrate ion. It has a linear concentration range of 1-6000 ppm nitrate and can be used over a wide pH range. The electrode does respond to some extent to anions other than nitrate, and some interferences do occur. These interferences are easily controlled by the use of cation exchange resins. The Corning known addition (spiking) method is used on all samples to insure correct electrode response in solutions containing variable background ionic composition. The electrode has the advantage of simplicity, speed, reproducibility, and accuracy. Work time saved using the electrode as opposed to the xylenol method is about 7 hr for the analysis of 20 samples. Error, and the need for repeating analysis, is much less frequent.
More Related Videos
08:05Measurement of the Potential Rates of Dissimilatory Nitrate Reduction to Ammonium Based on 14NH4+/15NH4+ Analyses via Sequential Conversion to N2O
Published on: October 7, 2020
08:23Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Precipitation Titration: Overview
A precipitation titration curve demonstrates the change in concentration of the titrant or analyte upon adding the...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
EDTA: Indirect and Alkalimetric Titration