Determination of polycyclic aromatic hydrocarbons by liquid chromatography-electrospray ionization mass spectrometry
M Takino1, S Daishima, K Yamaguchi
1Yokogawa Analytical Systems Inc., Osaka, Japan. masahiko_takino@agilent.com
Abstract:
Liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) using silver nitrate as a post-column reagent has been used for the determination of 10 polycyclic aromatic hydrocarbons (PAHs) in river water. In this method, after all the PAHs were separated by reversed-phase liquid chromatography, analytes formed complexes with silver cation by mixing with silver nitrate solution. The complexes then transfer the molecular ion, [M]+, of the PAHs by charge transfer using in source collision-induced dissociation. The positive ion ESI mass spectra of all PAHs tested in this study showed [M]+ as the base peak and abundant [M+Ag]+, [2M+Ag]- with very weak or no [2M+Ag]+. For the sample extraction, several solid-phase extraction parameters using the blue-chitin column were optimized. The limits of detection (S/N=3) of all PAHs for the spiked river water sample ranged from 0.001 to 0.03 ng/ml, and the detector responses were linear up to I ng/ml (correlation coefficients > or =0.0998). Repeatability and reproducibility were in the range from 4.3 to 6.8% and from 6.2 to 9.5%, respectively.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
08:54Determining Four Components in a Lipid Nanoparticle RNA Delivery System by Liquid Chromatography Combined with Evaporative Light Scattering Detector
Published on: May 30, 2025
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation