Related Experiment Video
Updated: Oct 4, 2026

Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
Published on: April 18, 2015
Kinetic evaluation of an i.v. bolus of MR contrast media
J T Heverhagen1, R C Funck, U Schwarz
1Department of Diagnostic Radiology, University Hospital, Philipps University, Baldingerstr, 35043 Marburg, Germany. heverhag@post.med.uni-marburg.de
Abstract:
Currently, it is assumed that the pharmacokinetic properties of the first minutes of an I.V. MR contrast media bolus are similar to those of an i.v. iodinated contrast media bolus used in CT. Correct timing of an MRA examination is crucial for obtaining sufficient arterial contrast. This study sought to evaluate the temporal change of arterial signal intensity within 150 s after i.v. bolus injection of Gd-DTPA. Thirty consecutive patients (14 women/16 men; mean age: 51 +/- 11 years) were prospectively examined with a 1.0 Tesla clinical scanner. A single axial slice was acquired in 1.25 sec with manufacturer provided gradient echo sequence through the aorta at the level of the renal arteries. Investigation was started simultaneously to the application of contrast media (0.1 mmol/kg bodyweight Gd-DTPA at three different rates 2 mL/sec, 3 mL/sec and 4 mL/sec) and repeated for 2.5 min. An additional echo Doppler examination excluded patients with any cardiac disorders. Maximum signal (1300% increase compared to the basic value) in the aorta was achieved 20 +/- 6 sec after start of bolus injection. Then a plateau phase was maintained for the remaining investigation time (2.5 min). No significant difference was shown for different injection rates. After a bolus injection of Gd-DTPA the arterial contrast remains on a high level for at least 2 min. However, correct timing of the bolus arrival is still crucial to discriminate arteries and veins. An injection rate between 2 mL/sec and 4 mL/sec has no influence on early contrast media dynamics.
Insights
Gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) provides high arterial contrast for at least two minutes after intravenous injection. Injection rates between 2-4 mL/sec do not significantly impact early contrast dynamics in MRA examinations.
Area of Science:
- Radiology
- Medical Imaging
- Pharmacokinetics
Background:
- Pharmacokinetic assumptions for intravenous (I.V.) MR contrast media boluses mirror those of CT contrast media.
- Accurate timing is critical for optimal arterial enhancement in MR angiography (MRA).
Purpose of the Study:
- To evaluate the temporal changes in arterial signal intensity following I.V. Gd-DTPA bolus injection over 150 seconds.
- To assess the impact of varying injection rates on early contrast dynamics.
Main Methods:
- Prospective study of 30 patients using a 1.0 Tesla scanner.
- Acquisition of a single axial slice through the aorta at the renal artery level.
- Simultaneous contrast media administration (0.1 mmol/kg Gd-DTPA at 2, 3, or 4 mL/sec) with data acquisition for 2.5 minutes.
Main Results:
- Maximum aortic signal intensity (1300% increase) achieved at 20 ± 6 seconds post-injection.
- A plateau phase of high arterial contrast maintained for the entire 2.5-minute investigation period.
- No significant differences in early contrast dynamics observed across the tested injection rates (2-4 mL/sec).
Conclusions:
- Intravenous Gd-DTPA bolus injection maintains high arterial contrast levels for at least 2 minutes.
- While contrast is sustained, precise timing of bolus arrival remains essential for differentiating arteries and veins.
- Injection rates between 2 mL/sec and 4 mL/sec do not influence the early dynamics of Gd-DTPA contrast media.
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies VII: Vascular Imaging