Determination of fat in raw and processed milks by the Gerber method: collaborative study
D H Kleyn1, J M Lynch, D M Barbano
1Rutgers University, Cook College, New Jersey Agricultural Experiment Station, Department of Food Science, New Brunswick 08903, USA.
Journal of AOAC International
|October 17, 2001
Summary
The Gerber method for milk fat determination shows reliable results whether using a weighed or pipetted test portion. A weighed portion is recommended for whole milk analysis, offering consistent accuracy across various fat levels.
Area of Science:
- Dairy Science
- Analytical Chemistry
- Food Analysis
Background:
- The Gerber method is a globally recognized, rapid technique for quantifying fat content in milk.
- International standardization of the test portion volume for the Gerber method is lacking.
- This study addresses the variability in test portion measurement for the Gerber method.
Purpose of the Study:
- To evaluate the performance of the Gerber method using a weighed test portion (11.13 g) versus a pipetted volume (10.77 mL).
- To compare the accuracy and precision of both Gerber method variations against the Mojonnier ether extraction reference method.
- To determine the optimal application of the Gerber method based on test portion measurement and milk fat content.
Main Methods:
- A collaborative study involving 11 and 10 laboratories for weighed and pipetted methods, respectively.
- Analysis of 10 milk samples (5 raw, 5 pasteurized) with varying fat content (0.96-5.48%).
- Comparison of results with Mojonnier ether extraction (AOAC Method 989.05) as the reference standard.
Main Results:
- Interlaboratory study statistics were comparable between weighed and pipetted test portions and across raw and processed milks.
- Pooled statistical performance: repeatability (sr) = 0.026, reproducibility (sR) = 0.047.
- The pipetted method showed significantly lower fat results (0.06% fat) compared to ether extraction, while the weighed method was slightly lower (0.02% fat).
Conclusions:
- The Gerber method demonstrates consistent performance regardless of test portion measurement method (weighed or pipetted).
- A trend of underestimation was observed with the weighed portion at lower fat concentrations (1-2%), but not with the pipetted portion.
- Recommendation for adoption of the Gerber method with a weighed test portion as First Action for whole milk analysis.