Measurement of spectral bandwidth, as exemplified with the Beckman "Enzyme Analyzer System TR spectrophotometer"
Related Experiment Video
Updated: Aug 16, 2026

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
Published on: December 22, 2015
Abstract:
This paper describes simple methods for determining spectral bandwidth by measurement and by calculation. We measured the spectral bandwidth of the monochromator from the Beckman Enzyme Analyzer TR, and found it to be 3.5-4.0 nm (av 3.8) by two different methods. We visually estimated it to be 4 nm. Using the specifications for the diffraction grafting, focal length, and fixed slit width, we calculated the theoretical spectral bandwidth to be 3.6 nm.