Related Experiment Video
Updated: Aug 25, 2026

Sedimentation Equilibrium of a Small Oligomer-forming Membrane Protein: Effect of Histidine Protonation on Pentameric Stability
Published on: April 2, 2015
Protein unfolding during reversed-phase chromatography: II. Role of salt type and ionic strength
J L McNay1, J P O'Connell, E J Fernandez
1Department of Chemical Engineering, University of Virginia, 102 Engineers' Way, Charlottesville, VA 22904-4741, USA.
Abstract:
While reversed-phase chromatography (RPC) may be a powerful method for purification of proteins at the analytical scale, both preparative and analytical applications have been hindered by the complex chromatographic behavior of proteins compared to small molecules. Further, preparative applications have been limited because of poor yields caused by the denaturing conditions involved. One means for modulating both the stability and chromatographic behavior of proteins is through the use of added salt. In this investigation, we show how salt type and ionic strength affect protein conformation on RPC surfaces. Exposure of amide groups of adsorbed BPTI was monitored using nuclear magnetic resonance (NMR) spectroscopy and hydrogen-deuterium isotope exchange. Sodium chloride, sodium acetate, and ammonium sulfate were studied at ionic strengths up to I = 0.375, with adsorption hold times being 5 min and 2 h. We found that increasing ionic strength decreased exposure of the exchange reporter groups in essentially all cases. However, even at the same ionic strength the level and distribution of residue protection varied with salt type and hold time. NaCl does not protect certain reporter groups at all, while those that it does protect to some degree at short hold times can exchange slightly more at longer times. The pattern and level of protection for NaAc at short times is similar to that for NaCl, but at longer times more uniform protection is seen as the reporter groups completely exposed at short times become more protected. For (NH(4))(2)SO(4) the pattern of protection at short hold time is similar to those of the other salts, although it protects all groups much more. This would be expected from the Hofmeister series. However, at longer times the level of protection with (NH(4))(2)SO(4) decreases below that of the other salts, while it uniquely protects all groups to nearly the same level. Such subtle variations in the protein structure would not have been detected without the measurements and analysis used here. Chromatographic retention times and peak shapes were obtained for the above systems. Variations of behavior were seen that could not be correlated with any of the above protection patterns and levels or even with heuristics such as the Hofmeister series. This suggests further conformational changes upon elution may be critical to the retention process. However, an excellent correlation was found between peak width at half-height and the average degree of unfolding, as indicated by the average level of isotopic exchange. Thus, while further studies are needed to definitively determine the connection between protein unfolding and retention, use of this correlation may improve designing and screening for chromatographic conditions that minimize protein unfolding.
More Related Videos
07:41Sequential Salt Extractions for the Analysis of Bulk Chromatin Binding Properties of Chromatin Modifying Complexes
Published on: October 2, 2017
10:41Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
Related Concept Videos
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Ionic Strength: Effects on Chemical Equilibria
In this solution, the primary cation—the calcium...
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...