Related Experiment Videos
CAP88-PC tritium ingestion model inconsistencies.
1Environmental Analysis Section, Westinghouse Savannah River Company, Aiken, SC 29808, USA. ali.simpkins@srs.gov
Health Physics
|October 24, 2001
Summary
The Environmental Protection Agency
Area of Science:
- Environmental Science
- Radiation Protection
- Nuclear Safety
Background:
- CAP88-PC is an EPA-approved code for National Emission Standard for Hazardous Pollutants (NESHAP) compliance.
- The code assesses radiation dose from environmental releases.
- Tritium dose calculations within CAP88-PC have known inconsistencies.
Purpose of the Study:
- To identify and address inconsistencies in the tritium ingestion dose methodology within the CAP88-PC code.
- To evaluate the impact of outdated parameters on tritium dose assessments.
- To propose corrections for improved accuracy in NESHAP compliance.
Main Methods:
- Comparative analysis of tritium ingestion dose methodology against other radionuclides in CAP88-PC.
- Identification of outdated tritium ingestion dose conversion factors.
- Review of hard-coded, outdated food consumption parameters specific to tritium.
Main Results:
- Significant inconsistencies were found in the tritium ingestion model compared to other radionuclides.
- Outdated tritium ingestion dose conversion factors and food consumption parameters were confirmed.
- Correcting these parameters could lead to an approximate 50% reduction in calculated tritium dose in specific scenarios.
Conclusions:
- The current CAP88-PC code contains outdated parameters affecting tritium dose calculations.
- Updating these parameters is crucial for accurate NESHAP compliance and radiation dose assessment.
- Revised calculations show a potential for substantial dose reduction, highlighting the need for code updates.