X-ray Absorption Spectroscopy of Tricarbonatodioxouranate(V), [UO(2)(CO(3))(3)](5)(-), in Aqueous Solution
T. I. Docrat1, J. F. W. Mosselmans, J. M. Charnock
1Research & Technology, BNFL Springfields, Preston PR4 0XJ, England, CLRC Daresbury Laboratory, Warrington WA4 4AD, England, Department of Chemistry, The University of Manchester, Manchester M13 9PL, England, and Research & Technology, BNFL Sellafield, Seascale, Cumbria CA20 1PG, England.
Abstract:
Actinyl ions (AnO(2)(+) and AnO(2)(2+)) are strongly complexed by CO(3)(2)(-) in aqueous solution, and tricarbonato complexes of UO(2)(2+) and NpO(2)(+), in particular, have been widely studied. Cyclic voltammetry shows that, whereas the Np(V)/Np(VI) couple is reversible in aqueous CO(3)(2)(-) solution, the analogous U couple is irreversible, suggesting significant conformational change on one-electron reduction of [UO(2)(CO(3))(3)](4)(-). EXAFS spectroscopy has been used to define the coordination geometry of the reduced species and shows that both axial and equatorial U-O distances increase on reduction, from 1.80 to 1.90 Å and from 2.43 to 2.50 Å, respectively. The basic geometry of the U complex is apparently unchanged by reduction so any conformational change which does occur must be subtle.
More Related Videos
12:05U2O5 Film Preparation via UO2 Deposition by Direct Current Sputtering and Successive Oxidation and Reduction with Atomic Oxygen and Atomic Hydrogen
Published on: February 21, 2019
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
Related Concept Videos
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent of conjugation in the...
UV–Vis Spectroscopy: Molecular Electronic Transitions
UV–Vis Spectroscopy: Woodward–Fieser Rules
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Atomization Methods