Background:
In patients with syncope and bundle branch block (BBB), syncope is suspected to be attributable to a paroxysmal atrioventricular (AV) block, but little is known of its mechanism when electrophysiological study is negative.
Methods And Results:
We applied an implantable loop recorder in 52 patients with BBB and negative conventional workup. During a follow-up of 3 to 15 months, syncope recurred in 22 patients (42%), the event being documented in 19 patients after a median of 48 days. The most frequent finding, recorded in 17 patients, was one or more prolonged asystolic pause mainly attributable to AV block; the remaining 2 patients had normal sinus rhythm or sinus tachycardia. The onset of the bradycardic episodes was always sudden but was sometimes preceded by ventricular premature beats. The median duration of the arrhythmic event was 47 seconds. An additional 3 patients developed nonsyncopal persistent III-degree AV block, and 2 patients had presyncope attributable to AV block with asystole. No patients suffered injury attributable to syncopal relapse.
Conclusions:
In patients with BBB and negative electrophysiological study, most syncopal recurrences have a homogeneous mechanism that is characterized by prolonged asystolic pauses, mainly attributable to sudden-onset paroxysmal AV block.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
09:20Microelectrode Array Recording of Sinoatrial Node Firing Rate to Identify Intrinsic Cardiac Pacemaking Defects in Mice
Published on: July 5, 2021
Related Concept Videos
Depolarizing Blockers: Mechanism of Action
Succinylcholine is the most commonly used depolarizing blocker. Chemically, it constitutes two molecules of acetylcholine joined together by an acetate methyl group. They act on the receptors in the same way as acetylcholine. Because succinylcholine...
Depolarizing Blockers: Pharmocokinetics
Electrophysiology of Normal Cardiac Rhythm
Mechanism of Cardiac Arrhythmias
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Dysrhythmias IV: Characteristics of Bradyarrhythmias