Related Experiment Video
Updated: Aug 9, 2026

Optimization of a Quantitative Micro-neutralization Assay
Published on: December 14, 2016
Titration emulation: a computer-assisted technique that simplifies the quantification of anti-dsDNA antibodies using
M Satoh1, K M Behney, A Mizutani
1Department of Medicine, University of Florida, Gainesville 32610-0221, USA. satohm@medicine.ulf.edu
Abstract:
Titers of anti-double-stranded (ds) DNA antibodies in sera from patients with systemic lupus erythematosus (SLE) using the Crithidia luciliae assay method were compared by conventional titration vs the titration emulation method (ImageTiter) to evaluate whether the latter assay can replace manual titration. Titers by the two methods were identical or within one dilution in 98% (41/42) of samples. A single sample showed a two-dilution difference. Titration emulation showed a tendency to under-estimate the titer of high titer anti-dsDNA samples, although the difference was small. Titration emulation is a suitable alternative to the conventional titration method, offering an accurate and cost-effective approach to quantification of anti-dsDNA antibodies.