Related Experiment Video
Updated: Oct 3, 2026

Measurement of the Pressure-volume Curve in Mouse Lungs
Published on: January 27, 2015
Relation of the static compliance curve and positive end-expiratory pressure to oxygenation during one-lung
P D Slinger1, M Kruger, K McRae
1Department of Anesthesia, University Health Network, University of Toronto, Toronto General Hospital, Ontario, Candada. peter.slinger@uhn.on.ca
Background:
Positive end-expiratory pressure (PEEP) is commonly applied to the ventilated lung to try to improve oxygenation during one-lung ventilation but is an unreliable therapy and occasionally causes arterial oxygen partial pressure (PaO(2)) to decrease further. The current study examined whether the effects of PEEP on oxygenation depend on the static compliance curve of the lung to which it is applied.
Methods:
Forty-two adults undergoing thoracic surgery were studied during stable, open-chest, one-lung ventilation. Arterial blood gases were measured during two-lung ventilation and one-lung ventilation before, during, and after the application of 5 cm H(2)O PEEP to the ventilated lung. The plateau end-expiratory pressure and static compliance curve of the ventilated lung were measured with and without applied PEEP, and the lower inflection point was determined from the compliance curve.
Results:
Mean (+/- SD) PaO(2) values, with a fraction of inspired oxygen of 1.0, were not different during one-lung ventilation before (192 +/- 91 mmHg), during (190 +/- 90), or after ( 205 +/- 79) the addition of 5 cm H(2)O PEEP. The mean plateau end-expiratory pressure increased from 4.2 to 6.8 cm H(2)O with the application of 5 cm H(2)O PEEP and decreased to 4.5 cm H(2)O when 5 cm H(2)O PEEP was removed. Six patients showed a clinically useful (> 20%) increase in PaO(2) with 5 cm H(2)O PEEP, and nine patients had a greater than 20% decrease in PaO(2). The change in PaO(2) with the application of 5 cm H(2)O PEEP correlated in an inverse fashion with the change in the gradient between the end-expiratory pressure and the pressure at the lower inflection point (r = 0.76). The subgroup of patients with a PaO(2) during two-lung ventilation that was less than the mean (365 mmHg) and an end-expiratory pressure during one-lung ventilation without applied PEEP less than the mean were more likely to have an increase in PaO(2) when 5 cm H(2)O PEEP was applied.
Conclusions:
The effects of the application of external 5 cm H(2)O PEEP on oxygenation during one-lung ventilation correspond to individual changes in the relation between the plateau end-expiratory pressure and the inflection point of the static compliance curve. When the application of PEEP causes the end-expiratory pressure to increase from a low level toward the inflection point, oxygenation is likely to improve. Conversely, if the addition of PEEP causes an increased inflation of the ventilated lung that raises the equilibrium end-expiratory pressure beyond the inflection point, oxygenation is likely to deteriorate.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Respiratory Volumes and Capacities I
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...