Related Experiment Video
Updated: Aug 2, 2026

Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique
Published on: May 15, 2013
Results of respiratory mechanics analysis in the critically ill depend on the method employed
F Ruiz-Ferrón1, L Rucabado Aguilar, S Ruiz Navarro
1Intensive Care Unit, University Hospital Ciudad de Jaén, Avenida del Ejercito Español 10, 23007 Jaén, Spain. FR271061@terra.es
Objective:
To compare the measurements of total resistance and dynamic elastance determined by different techniques of respiratory mechanics analysis based on the time or frequency domains.
Design:
Prospective study.
Setting:
A 12-bed medical and surgical intensive care unit in a 700-bed university hospital.
Patients:
Eighteen sedoparalyzed patients who needed controlled mechanical ventilation for acute or chronic acute respiratory failure.
Measurements:
The total resistance and dynamic elastance in the time domain were determined by the occlusion technique and by multiple linear regression. The Fourier analysis was used to study the impedance of the respiratory system for elastance and resistance values in the frequency domain.
Results:
The ANOVA analysis of the elastance variable showed no statistical differences (Ef: 41.4+/-19.0 cmH(2)O/l, Emlr: 40.8+/-17.2 cmH(2)O/l Edyn,occ: 39.5+/-14.0 cmH(2)O/l; ns) and the correlation was very good (r=0.8-0.9). The total resistances were less with multiple linear regression (13.5+/-9.3 cmH(2)O/l per s, p<0.05) than Rmax (17.0+/-11.9 cmH(2)O/l per s) or Rf (17.6+/-10.2 cmH(2)O/l per s). There were no differences between Rmax and Rf (p=0.7) and the correlation between resistances was 0.7-0.9. The agreement analysis for variables without statistical differences showed the following limits: Edyn,occ-f: -17 to 13 cmH(2)O/l; Edyn,occ-mlr: -12 to 9 cmH(2)O/l; Emlr-f: -6 to 8 cmH(2)O/l; Rmax-f: -18 to 19 cmH(2)O/l per s. This last range was related to the autoPEEP level (r=0.9).
Conclusion:
The wide agreement limits show that respiratory mechanics analysis is very dependent on the measurement technique used, particularly for resistance, perhaps due to the higher dependence on frequency.
More Related Videos
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Acute Respiratory Failure-IV
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...