Related Experiment Video
Updated: Jul 27, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
MR renography with low-dose gadopentetate dimeglumine: feasibility
V S Lee1, H Rusinek, G Johnson
1Department of Radiology-MRI, New York University, 530 First Ave, HCC Basement, New York, NY 10016, USA. lee@mri.med.nyu.edu
Purpose:
To develop a low-dose magnetic resonance (MR) renographic method performed with and without an angiotensin converting enzyme (ACE) inhibitor and in conjunction with gadolinium-enhanced MR angiography in patients with suspected renovascular disease.
Materials And Methods:
Thirty-two patients underwent MR renography (turbo fast low-angle shot sequence: repetition time, 5 msec; echo time, 2.3 msec; flip angle, 15 degrees; one coronal image acquired every 2 seconds for 4 minutes) following intravenous injection of 2 mL of gadopentetate dimeglumine, which was repeated following intravenous injection of an ACE inhibitor. Contrast material-enhanced MR angiography was also performed. On the basis of renographic findings, renal cortex and renal medulla enhancement curves and normalized enhancement ratios were analyzed.
Results:
The cortex and medulla showed an early transient period of enhancement within 20 seconds (vascular phase). During 1-2 minutes, a second, gradual increase in medullary enhancement, reflecting transit of filtered contrast material, was observed that was significantly greater in patients with a serum creatinine level less than 2 mg/dL (177 micromol/L) than in those with a level of 2 mg/dL or greater (P < .01). After injection of the ACE inhibitor, patients with elevated creatinine levels showed low renal medullary enhancement regardless of the presence of renal artery stenosis (RAS). However, in patients with creatinine less than 2 mg/dL, medullary enhancement ratios after injection of the ACE inhibitor were consistently lower in patients with RAS of 50% or greater than in those without stenosis (P = .02 to .08).
Conclusion:
Low-dose MR renography can be performed in the clinical setting before and after injection of an ACE inhibitor, and its potential use for evaluating decreased renal function as a consequence of RAS is promising.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies VII: Vascular Imaging

