Related Experiment Video
Updated: Aug 9, 2026

15N CPMG Relaxation Dispersion for the Investigation of Protein Conformational Dynamics on the µs-ms Timescale
Published on: April 19, 2021
Potential bias in NMR relaxation data introduced by peak intensity analysis and curve fitting methods
J H Viles1, B M Duggan, E Zaborowski
1Department of Molecular Biology and Skaggs Institute for Chemical Biology, The Scripps Research Institute, La Jolla, CA 90237, USA.
Abstract:
We present an evaluation of the accuracy and precision of relaxation rates calculated using a variety of methods, applied to data sets obtained for several very different protein systems. We show that common methods of data evaluation, such as the determination of peak heights and peak volumes, may be subject to bias, giving incorrect values for quantities such as R1 and R2. For example, one common method of peak-height determination, using a search routine to obtain the peak-height maximum in successive spectra, may be a source of significant systematic error in the relaxation rate. The alternative use of peak volumes or of a fixed coordinate position for the peak height in successive spectra gives more accurate results, particularly in cases where the signal/noise is low, but these methods have inherent problems of their own. For example, volumes are difficult to quantitate for overlapped peaks. We show that with any method of sampling the peak intensity, the choice of a 2- or 3-parameter equation to fit the exponential relaxation decay curves can dramatically affect both the accuracy and precision of the calculated relaxation rates. In general, a 2-parameter fit of relaxation decay curves is preferable. However, for very low intensity peaks a 3 parameter fit may be more appropriate.
More Related Videos
07:24Paramagnetic Relaxation Enhancement for Detecting and Characterizing Self-Associations of Intrinsically Disordered Proteins
Published on: September 23, 2021
09:25NMR 15N Relaxation Experiments for the Investigation of Picosecond to Nanoseconds Structural Dynamics of Proteins
Published on: November 1, 2024
Related Concept Videos
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied first.
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution
NMR Spectrometers: Resolution and Error Correction
¹H NMR Signal Integration: Overview
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR