Related Experiment Video
Updated: Aug 9, 2026

Probing C84-embedded Si Substrate Using Scanning Probe Microscopy and Molecular Dynamics
Published on: September 28, 2016
Imaging of electrically detected magnetic resonance of a silicon wafer
1Yamagata Research Institute of Technology, Yamagata 990-2473, Japan.
Abstract:
An imaging technique of electrically detected magnetic resonance (EDMR) was newly developed. Because the EDMR signal is obtained from paramagnetic recombination centers, one may expect the image to represent the distribution of defect and/or impurity sites in the sample. We successfully obtained EDMR images of a light-illuminated silicon plate 8 mm in width and 15 mm in length, which was cut from a silicon wafer (n-type, 100 Omega cm), under ESR irradiation at a frequency of 890 MHz (wavelength, 340 mm). The reproducibility of the EDMR image obtained from a sample was amply satisfactory. When the oxidized surface of the silicon was removed, the EDMR signal disappeared. Although the EDMR signal reappeared when the surface of the sample became reoxidized, the EDMR image obtained was slightly different from the earlier one. This finding shows that the EDMR image obtained from the sample shows the distribution of defects at the Si/SiO(2) interface.