Related Experiment Video
Updated: Oct 3, 2026

Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Feasibility of a short acquisition protocol for whole-body positron emission tomography with fluorine-18
A K Paul1, M Tatsumi, K Fujino
1Division of Tracer Kinetics, Biomedical Research Center, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, 565-0871, Suita, Osaka, Japan.
Abstract:
The conventional protocol for whole-body positron emission tomography (PET) with fluorine-18 fluorodeoxyglucose (FDG) requires a total acquisition time of 40-60 min, which is inconvenient for many oncological patients owing to fatigue and discomfort. This study examined the feasibility of a short protocol for whole-body PET. A phantom containing six "hot" spheres of gradually increasing diameter (10-38 mm) was imaged using a dedicated PET scanner for 20, 40, 60, 80, 120 and 600 s at various count rates. Thirty-four patients with various neoplasms underwent whole-body emission scans for 1 min per bed position 1 h after intravenous injection of 370 MBq of FDG (short protocol). A standard simultaneous transmission-emission acquisition for 10 min per bed position was performed thereafter. The images were reconstructed using an iterative algorithm. At a count rate of 40 kcps, which is close to the average count rate obtained in a whole-body FDG PET study, the 60-s image visualised five spheres, of which the smallest was 13 mm in size. Despite the better image quality, lesion detection was not improved in images acquired for more than 60 s (80-600 s). Only three of the six spheres could be detected in images acquired for less than 60 s. In the patient study, the standard protocol visualised 120 tumour lesions, of which 93 (78%) could be detected using the short protocol. Among the non-visualised lesions, 22 (82%) were < or =1.5 cm in size and 17 (63%) were lymph nodes. It is concluded that the proposed short protocol for whole-body FDG PET has a reasonably high detection rate and may be suitable for patients who are unable to undergo scanning for a prolonged period. It may also be useful as a pre-scan guide before a standard whole-body acquisition.
More Related Videos
10:20Automation of a Positron-emission Tomography (PET) Radiotracer Synthesis Protocol for Clinical Production
Published on: October 26, 2018
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...