Related Experiment Video
Updated: Jul 11, 2026

Continuous Instream Monitoring of Nutrients and Sediment in Agricultural Watersheds
Published on: September 26, 2017
Comparison of instream methods for measuring hydraulic conductivity in sandy streambeds
M K Landon1, D L Rus, F E Harvey
1US Geological Survey, Lincoln, NE 68508, USA. landon@usgs.gov
Abstract:
Streambed hydraulic conductivity (K) values were determined at seven stream transects in the Platte River Basin in Nebraska using different instream measurement techniques. Values were compared to determine the most appropriate technique(s) for use in sandy streambeds. Values of K determined from field falling- and constant-head permeameter tests analyzed using the Darcy equation decreased as permeameter diameter increased. Seepage meters coupled with hydraulic gradient measurements failed to yield K values in 40% of the trials. Consequently, Darcy permeameter and seepage meter tests were not preferred approaches. In the upper 0.25 m of the streambed, field falling- and constant-head permeameter tests analyzed with the Hvorslev solution generally had similar K values that were significantly greater than those determined using the Hazen grain-size, Bouwer and Rice slug test for anisotropic and isotropic conditions, and Alyamani and Sen grain-size methods; median differences between these tests and the Hvorslev falling-head 60 cm diameter permeameter were about 8, 9, 17, and 35 m/day, respectively. The Hvorslev falling-head permeameter test is considered the most robust method for measuring K of the upper 0.25 m of the streambed because of the inherent limitations of the empirical grain-size methods and less sediment disturbance for permeameter than slug tests. However, lateral variability in K along transects on the Platte, North Platte, and Wood Rivers was greater than variability in K between valid permeameter, grain-size, or slug tests, indicating that the method used may matter less than making enough measurements to characterize spatial variability adequately. At the Platte River tributary sites, the upper 0.3 m of the streambed typically had greater K than sediment located 0.3 to 2.5 m below the streambed surface, indicating that deposits below the streambed may limit ground water/surface water fluxes. The Hvorslev permeameter tests are not a practical measurement approach for these greater depths. Thus, selection of a method for measuring streambed K needs to consider the vertical location of the sediments that are most likely to limit the rate of ground water/surface water interaction.
More Related Videos
08:09Wastewater Irrigation Impacts on Soil Hydraulic Conductivity: Coupled Field Sampling and Laboratory Determination of Saturated Hydraulic Conductivity
Published on: August 19, 2018
07:21Measurements of Soil Water Potential and Conductivity based on a Simple Evaporation Experiment using a Hydraulic Property Analyzer
Published on: August 9, 2024
Related Concept Videos
Uniform Depth Channel Flow
Rapidly Varying Flow
Weir: Problem Solving
Design Example: Design of an Irrigation Channel