Related Experiment Video
Updated: Jul 30, 2026

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Mechanisms whereby rapid RV pacing causes LV dysfunction: perfusion-contraction matching and NO
L A Nikolaidis1, T Hentosz, A Doverspike
1Department of Medicine, Allegheny General Hospital, MCP-Hahnemann University School of Medicine, Pittsburgh, Pennsylvania 15212, USA.
Abstract:
Incessant tachycardia induces dilated cardiomyopathy in humans and experimental models; mechanisms are incompletely understood. We hypothesized that excessive chronotropic demands require compensatory contractility reductions to balance metabolic requirements. We studied 24 conscious dogs during rapid right ventricular (RV) pacing over 4 wk. We measured hemodynamic, coronary blood flow (CBF), myocardial O(2) consumption (MVO(2)) responses, myocardial nitric oxide (NO) production, and substrate utilization. Early pacing (6 h) resulted in decreased heart rate (HR)-adjusted coronary blood flow (CBF), MVO(2) (CBF/beat: 0.33 +/- 0.02 to 0.19 +/- 0.01 ml, P < 0.001, MVO(2)/beat: 0.031 +/- 0.002 to 0.016 +/- 0.001 ml O(2), P < 0.001), and contractility [left ventricular (LV) first derivative pressure (dP/dt)/LV end-diastolic diameter (EDD): 65 +/- 4 to 44 +/- 3 mmHg x s(-1) x mm(-1), P < 0.01], consistent with flow-metabolism-function coupling, which persisted over the first 72 h of pacing (CBF/beat: 0.15 +/- 0.01 ml, MVO(2)/beat: 0.013 +/- 0.001 ml O(2), P < 0.001). Thereafter, CBF per beat and MVO(2) per beat increased (CBF/beat: 0.25 +/- 0.01 ml, MVO(2)/beat: 0.021 +/- 0.001 ml O(2) at 28 days, P < 0.01 vs. 72 h). Contractility declined [(LV dP/dt)/LVEDD: 19 +/- 2 mmHg x s(-1) x mm(-1), P < 0.0001], signifying flow-function mismatch. Cardiac NO production, endothelial NO synthase expression, and fatty acid utilization decreased in late phase, whereas glycogen content and lactate uptake increased. Incessant tachycardia induces contractile, metabolic, and flow abnormalities reflecting flow-function matching early, but progresses to LV dysfunction late, despite restoration of flow and metabolism. The shift to flow-function mismatch is associated with impaired myocardial NO production.
Related Concept Videos
Mechanism of Cardiac Arrhythmias
Pathophysiology of Cardiac Performance
Pathophysiology of Heart Failure
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Mitral Stenosis I: Introduction
Heart Failure II: Pathophysiology