Related Experiment Video
Updated: Aug 4, 2026

Modeling Encephalopathy of Prematurity Using Prenatal Hypoxia-ischemia with Intra-amniotic Lipopolysaccharide in Rats
Published on: November 20, 2015
Are very low birth weight infants born at high altitude at greater risk for adverse outcomes?
1Pediatrix-Obstetrix Center for Research and Education, Pediatrix Medical Group, Inc, Denver, Colorado, USA.
Objective:
To determine if neonatal intensive care at higher altitudes was associated with any variation in mortality or morbidity.
Methods:
We reviewed demographic and outcome data on 5450 neonates with birth weights between 500 and 1500 g cared for in 76 different level II and III neonatal intensive care units (NICUs). The altitude break point of 4300 feet was prospectively chosen. Care was provided at 63 NICUs located below 4300 feet, "low-altitude," (n = 4534 neonates) and at 13 NICUs at or above 4300 feet, "high-altitude" (n = 916 neonates).
Results:
Compared with neonates cared for at low altitude, neonates cared for at high altitude were more often non-Hispanic white and exposed to prenatal steroids. Neonates born at high altitude were more often treated with surfactant (60% vs 53%, P <.01). At 28 days of age, neonates cared for at high altitude were less often in room air (33% vs 50%, P <.01) compared with neonates cared for at low altitude. However, when corrected for barometric pressure, the calculated partial pressure of inspired oxygen at 28 days of age was lower for neonates cared for at high altitude compared with low altitude (165 +/- 80 vs 183 +/- 57, P <.01). There were no differences in the rates of mortality, severe intraventricular hemorrhage (grades 3 and 4), severe retinopathy of prematurity (stages 3 and 4), or necrotizing enterocolitis requiring surgical treatment.
Conclusions:
Being cared for at NICUs located above 4300 feet above sea level was not associated with any increase in adverse events compared with NICUs located below 4300 feet.
Related Concept Videos
Factors Affecting Respiration
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulmonary Tuberculosis I
Causative Organism
The primary infectious agent causing tuberculosis is Mycobacterium tuberculosis, a slow-growing, acid-fast, aerobic rod that exhibits sensitivity to heat and ultraviolet light. Instances of Mycobacterium bovis and Mycobacterium avium contributing to the development of TB infection are rare.
Mode of...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Pathophysiology of Diabetes
Type 1 diabetes is characterized by autoimmune-mediated destruction of pancreatic β cells, with environmental factors potentially triggering this process in genetically susceptible individuals. Despite many not having a family history, certain genes increase susceptibility, suggesting a...
Atelectasis II: Pathophysiology

