Ultrasonography for the evaluation of forearm interosseous membrane disruption in a cadaver model
J I Jaakkola1, D H Riggans, G M Lourie
1Department of Orthopaedics, Atlanta Medical Center, Atlanta, GA, USA.
Abstract:
Recognition of interosseous membrane disruption associated with radial head injury and Essex-Lopresti injury is important, especially if radial head excision is contemplated. Because a widely accepted method to diagnose interosseous membrane disruption does not exist, we evaluated the accuracy of ultrasonography to diagnose this injury in a cadaver model. Nine pairs of cadaver forearms were randomized into 2 groups. The central third of the interosseous membrane of forearms of group 1 was cut, whereas it was visualized but not cut in group 2. A dynamic ultrasound examination was performed to determine interosseous membrane integrity, and static images were made. The static images were evaluated by 2 other radiologists and interpretations were recorded. One radiologist incorrectly interpreted 1 pair of forearms; the other 2 radiologists were 100% accurate. The accuracy of ultrasonography in detecting interosseous injuries was 96% with our methods.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Bones of the Upper Limb: Humerus
Bones of the Upper Limb: Ulna
Imaging Studies II: Ultrasonography