Effectiveness of abdominal compression during helical renal CT
E M Caoili1, R H Cohan, M Korobkin
1Department of Radiology, University of Michigan Medical Center, Ann Arbor 48109-9723, USA.
Rationale And Objectives:
The authors performed this study to assess the effect of abdominal compression on opacification and distention of the proximal renal collecting system during helical computed tomography (CT).
Materials And Methods:
Abdominal compression was applied during helical CT in 31 patients who were scanned 150 and 300 seconds after initiating a dynamic bolus injection of contrast material. Two reviewers assessed renal collecting system opacification and measured the maximal short-axis diameter of the collecting system at three locations: the upper pole, the lower pole, and the proximal ureter. A similar evaluation was performed in a control group of 29 patients who underwent CT without compression at 300 seconds after initiating the injection of contrast material.
Results:
Both reviewers noted collecting system opacification at all locations in 52 of 56 noncompressed collecting systems scanned at 300 seconds, 57 of 59 compressed collecting systems scanned at 300 seconds, but only 26 of 59 compressed collecting systems scanned at 150 seconds. Measured collecting system distention was statistically significantly greater at 300 seconds in patents who received compression than in patients who did not (P = .0013). For patients who received compression, measured collecting system distention was statistically significantly greater on scans obtained at 300 seconds than on scans obtained at 150 seconds (P = .0001).
Conclusion:
Abdominal compression during renal helical CT produces a detectable increase in renal collecting system distention. In patients who receive compression, scanning at 300 seconds rather than at 150 seconds results in greater collecting system distention and more consistent opacification.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
04:37Improved Home Blood Pressure Control by CT-guided Ozone-mediated Renal Denervation for Patients with Resistant Hypertension
Published on: June 6, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging