A potential role for immune activation in hemodialysis hypotension

M Tomita1, D Malhotra, S Dheenan

  • 1Department of Medicine, Medical College of Ohio, Toledo 43614, USA.

Renal Failure
|December 1, 2001
PubMed

Related Concept Videos

Hormonal Regulation01:33

Hormonal Regulation

The renin-aldosterone system is an endocrine system which guides the renal absorption of water and electrolytes, thus managing blood pressure and osmoregulation. Activation of the system begins in the kidneys with a small cluster of cells adjacent to the afferent and efferent blood vessels of the renal corpuscle. As the nephrons are filtering blood, juxtaglomerular cells monitor blood pressure. If they detect a decrease in pressure, they release the hormone renin into the bloodstream.
Hypertension II: Pathophysiology01:29

Hypertension II: Pathophysiology

Hypertension is a chronic condition in which the blood's force against artery walls is excessively high, posing risks such as heart disease. The condition's underlying mechanisms involve complex interactions among the cardiovascular, kidney, and autonomic nervous systems.Renin-Angiotensin-Aldosterone System (RAAS): This system significantly influences blood pressure regulation. When blood pressure decreases, the kidneys secrete renin. This enzyme transforms angiotensinogen, a plasma protein,...
Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
Hemodialysis III: Nursing Management01:25

Hemodialysis III: Nursing Management

The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this measurement...
Diabetic Nephropathy01:28

Diabetic Nephropathy

Definition Diabetic nephropathy is a chronic kidney complication that results from prolonged hyperglycemia.Prevalence It is the most common cause of chronic kidney disease (CKD) and end-stage renal disease (ESRD) worldwide, affecting up to half of individuals with diabetes.Pathophysiology • Sustained hyperglycemia triggers multiple hemodynamic and metabolic changes in the kidney. • Early in the disease, increased renal blood flow and glomerular hyperfiltration occur due to afferent arteriolar...