Related Experiment Video
Updated: Jul 30, 2026

Hemocompatibility Testing of Blood-Contacting Implants in a Flow Loop Model Mimicking Human Blood Flow
Published on: March 5, 2020
Microembolic signal counts increase during hyperbaric exposure in patients with prosthetic heart valves
R W Baumgartner1, A Frick, C Kremer
1Department of Neurology, University of Zurich, Switzerland. ralf.baumgartner@nos.usz.ch
Background:
Patients with prosthetic heart valves have an increased risk of thromboembolic events, and transcranial Doppler sonography reveals microembolic signals. Whereas microembolic signals were initially assumed to be of particulate matter, recent studies suggest that they are partially gaseous in origin. If this is true, alteration of environmental pressure should change microembolic signal counts. We undertook this study to evaluate the influence of hyperbaric exposure on microembolic signal counts in persons with prosthetic heart valves.
Methods And Results:
Microembolic signal counts were monitored by transcranial Doppler sonography of both middle cerebral arteries under normobaria (normobaria 1), 2 subsequent periods of hyperbaria (2.5 and 1.75 bar), and a second period of normobaria (normobaria 2) in 15 patients with prosthetic heart valves. Each monitoring period lasted 30 minutes. Compression and decompression rates were 0.1 bar/min. Microembolic signal counts increased from 20 (12-78) at normobaria 1 to 79 (30-165) at 2.5 bar (P <.01 vs normobaria 1 and 2), decreased to 44 (18-128) at 1.75 bar (P <.01 vs normobaria 1 and 2.5 bar; P <.001 vs normobaria 2), and returned to 20 (8-96) at normobaria 2 (values are medians and 95% confidence intervals).
Conclusions:
Our results strongly suggest that gaseous bubbles are underlying material for part of the microembolic signals detected in patients with prosthetic heart valves.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Mitral Stenosis II: Clinical features and Diagnostic Tests
Aortic Regurgitation II: Clinical Features and Diagnostic Tests