[Balloon pulmonary valvuloplasty in a 1,680 g preterm infant]
M Cazzaniga1, M Riaza, V Soler
1Servicio de Pediatría y Cardiología Pediátrica, Hospital de Madrid Montepríncipe, Spain. marcazza@inicia.es
Anales Espanoles De Pediatria
|December 4, 2001
Abstract:
We report a preterm infant weighing 1,680-g with critical pulmonary stenosis. Pulmonary balloon valvuloplasty was successfully performed using a = 1.15 balloon/annulus ratio.