Related Experiment Video
Updated: Oct 3, 2026

Use of Electromagnetic Navigational Transthoracic Needle Aspiration (E-TTNA) for Sampling of Lung Nodules
Published on: May 23, 2015
CT-guided percutaneous needle biopsy of intrathoracic lesions by using the transsternal approach: experience in 37
Sanjay Gupta1, Michael J Wallace, Frank A Morello
1Section of Vascular and Interventional Radiology, Division of Diagnostic Imaging, University of Texas M.D. Anderson Cancer Center, 1515 Holcombe Blvd, Box 57, Houston, TX 77030-4009, USA.
Purpose:
To report our experience with computed tomography (CT)-guided coaxial needle biopsy of intrathoracic lesions by using the transsternal approach.
Materials And Methods:
Medical records of 37 consecutive patients who underwent CT-guided transsternal biopsy of intrathoracic lesions were evaluated retrospectively. A coaxial needle technique was used in all patients; an 18-gauge needle was used for transsternal penetration, through which a 22-gauge needle was passed to obtain fine-needle aspirates. Five patients also underwent core-needle biopsy with a coaxially introduced 20-gauge needle. Medical records were reviewed for lesion size and location, needle path, number of needle penetrations, reasons for failure, biopsy results, and complications.
Results:
The transsternal approach was used in mediastinal (n = 32) or intrapulmonary (n = 5) lesions. Transsternal needle sampling of the target lesion was successful in 35 patients. In the remaining two, adequate angling of the transsternal needle could not be achieved. Extrapleural access to the mediastinal lesions was achieved in all but one patient in whom the 22-gauge needle traversed the lung. Major vessels were avoided in most patients; the 22-gauge needle was safely passed through the brachiocephalic vein in one patient with a retrotracheal mass. Thirty-two (91%) of the 35 biopsies yielded diagnostic specimens. No major complications were encountered. Minor complications were pneumothorax in one patient and mediastinal hematoma in another.
Conclusion:
The CT-guided transsternal approach for coaxial core-needle biopsy allows safe access to masses in various locations in the mediastinum and anteromedial lung.
Related Concept Videos
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...