Comparison and evaluation of copper complex-containing siloxane polymers as stationary phases for capillary gas
1Department of Chemistry, National Taiwan University, Taipei, Taiwan. cyliu@ccms.ntu.edu.tw. cyliu@ccms.ntu.edu.tw
Abstract:
Two metallomesogenic polymers. P-C11CuC18 and P-C11CuC12 consisting of flexible aliphatic side chains with copper carboxylate complexes have been synthesized on the basis of addition reactions with polysiloxane. The applicability of the prepared columns to the analysis of phthalate esters that are of environmental concern was assessed. For preparation of the capillary column with its wall coated with the metallomesogenic polymer, both static and dynamic methods were employed. Factors affecting the retention and the sample selectivity on both columns were examined. A better separation of phthalates was achieved with P-C11CuC18 than P-C11CuC12. The former phase showed a higher solute-solvent interaction than the latter. With static coating, the wall-coated P-C11CuC18 capillary column (15 m x 250 microm I.D.) showed that the baseline separation of all 14 phthalates could be achieved within 38 min with high reproducibility. The calibration graphs for phthalate ester determination were linear over the range of 10-625 microg ml(-1). The mass detection limits were lower than the ng range based on three times the standard deviation of seven measurements of the lowest peak that could be detected.
More Related Videos
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...