Related Experiment Video
Updated: Aug 10, 2026

Measurement of Greenhouse Gas Flux from Agricultural Soils Using Static Chambers
Published on: August 3, 2014
Flux of gases across the air-water interface studied by reversed-flow gas chromatography
K A Rashid1, D Gavril, N A Katsanos
1Department of Chemistry, University of Patras, Greece.
Abstract:
In the present work the reversed-flow gas chromatographic technique was applied for the study of flux of gases across the air-water interface. The model system was vinyl chloride-water, which is of great significance in food and environmental chemistry. Using suitable mathematical analysis, equations were derived by means of which the following physicochemical quantities were calculated: diffusion coefficient of vinyl chloride (VC) into water, partition coefficient of VC between the water (at the interface and the bulk) and the carrier gas nitrogen, overall mass transfer coefficients of VC in the gas (nitrogen) and the liquid (water), gas and liquid film transfer coefficients of VC, gas and liquid phase resistances for the transfer of VC into the water, and finally the thickness of the stagnant film in the liquid phase, according to the two-film theory of Whitman. From the variation of the above parameters with temperature, as well as the volume and the free surface area of the water, useful conclusions concerning the mechanism for the transfer of VC into water were extracted. These are discussed in comparison with the same parameters calculated from empirical equations or determined experimentally by other techniques.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:24Combustion Chemistry of Fuels: Quantitative Speciation Data Obtained from an Atmospheric High-temperature Flow Reactor with Coupled Molecular-beam Mass Spectrometer
Published on: February 19, 2018
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...