Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Trace level analysis of polycyclic aromatic hydrocarbons in surface waters by solid phase extraction (SPE) and gas
P W Crozier1, J B Plomley, L Matchuk
1Ontario Ministry of the Environment (MOE), Laboratory Services Branch, Etobicoke, Ontario, Canada. patrick.crozier@ene.gov.on.ca
Abstract:
Ontario Provincial Water Quality Objectives for polycyclic aromatic hydrocarbons (PAHs) in surface waters require low parts per trillion (ng L(-1))/high parts per quadrillion (pg L(-1)) detection limits. To meet these monitoring requirements, a solid phase extraction-gas chromatography-ion trap mass spectrometry (SPE-GC-ITMS) method was developed. Seventeen priority PAHs commonly monitored in surface and drinking waters were examined using an external ionization ion trap mass spectrometer operated in selected ion monitoring (SIM) mode. Under 70 eV electron ionization (El) conditions, both the quantitative [M]+* ion and confirmatory [M - 2H]+* ion were formed in classical abundance ratios. Each of these ion species was isolated in the ion trap using a specific scan function. However, to overcome poor levels of confirmatory ion abundance which otherwise restrict PAH method detection limits (MDLs), the abundance of [M - 2H]+* ions was augmented during isolation by causing the dissociation of [M]+* with the broad-band waveform used for high mass ion ejection. Augmenting the [M - 2H]+* signal intensity facilitated the achievement of MDLs of approximately 1 ng L(-1). PAHs in surface water samples that were not detected by current Ontario Ministry of the Environment high-performance liquid chromatography (HPLC)-fluorescence and GC-single-stage quadrupole mass spectrometry methods were detected and quantified using the ion trap mass spectrometry SIM method. The data produced by all three methods on natural water samples fortified at sub-parts per billion (ppb) levels were comparable. When applied to Standards Council of Canada/Canadian Association for Environmental Analytical Laboratories (SCC/CAEAL, www.CAEAL.ca) accreditation audit samples, the SPE-GC-ITMS method results met all performance evaluation criteria.
More Related Videos
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...