Related Experiment Videos
An application of permeable reactive barrier technology to petroleum hydrocarbon contaminated groundwater
Turlough F Guerin1, Stuart Horner, Terry McGovern
1Shell Engineering Ltd, NSW State Office, Granville, Australia. turlough.guerin@shell.com.au
Abstract:
A funnel and gate permeable reactive barrier was designed and built to treat groundwater contaminated with dissolved phase toluene. ethyl benzene. and xylene and n-alkanes in the C6-C36 fraction range. Removal efficienicies for the funnel and gate system varied from 63% to 96% for the monocyclic aromatic hydrocarbons. Average removal efficiencies for C6-C9, C10-C14, and C15-C28 fraction ranges were 69.2%, 77.6% and 79.5%. respectively. The lowest average removal efficiencies were 54% for the C29-C36 n-alkane fraction. The overall average removal efficiency for the funnel and gate system towards petroleum hydrocarbons present in the groundwater was 72% during the 10 month period over which the data were collected, and has allowed relevant water quality objectives to be met.