Abstract:
A method was developed for determination of total iodine content in different standard reference materials (SRMs) and seafood products by inductively coupled plasma/mass spectrometry (ICP/MS). If iodine is present as iodide and nitric acid is used in the wet digestion system, the observed signal is not stable when iodine is measured by ICP/MS at m/z 127. To stabilize the iodine signal, 3% ammonia solution (1 + 1, v/v) was added to the digest. The limit of quantitation of the method, defined as 6 times the standard deviation in the blank solution (n = 20) was estimated to be 15 mg/kg (using 0.2 g dry mass and a dilution factor of 50). The precision, expressed as repeatability of the iodine concentration, varied between 3.2 and 12% in SRMs, with concentrations of 4.70-0.17 mg/kg dry matter. The described method was compared with a method using tetramethylammonium hydroxide extraction. Both methods showed good precision and trueness by analyses of SRMs. The 2 methods were used to determine iodine in seafood from the Barents Sea, the Norwegian Sea, and the North Sea. The results showed great variation between different fish species as well as between individuals within a species. The lowest values of iodine were recorded in muscle of ling (Molva molva) with a mean of 0.07 mg/kg fresh weight and a variation between 0.03 and 0.11 mg/kg fresh weight. The highest values were found in cod (Gadus morhua) from the Barents Sea, with a mean of 2.5 mg/kg and a variation between 0.7 and 12.7 mg/kg fresh weight.
More Related Videos
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
04:54Assessing Mineral Availability in Fish Feeds using Complementary Methods Demonstrated with the Example of Zinc in Atlantic Salmon
Published on: October 29, 2021
Related Concept Videos
Redox Titration: Iodimetry and Iodometry
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab