Related Experiment Video
Updated: Jul 19, 2026

High Content Screening Analysis to Evaluate the Toxicological Effects of Harmful and Potentially Harmful Constituents (HPHC)
Published on: May 10, 2016
Analysis of toxicokinetic data using NONMEM: impact of quantification limit and replacement strategies for censored
J P Hing1, S G Woolfrey, D Greenslade
1Department of Anaesthesia, University of Newcastle upon Tyne.
Abstract:
The purpose of this study was to examine how best to incorporate plasma samples which fall below an assay's lower limit of quantification into the process of toxicokinetic data modeling. Secondly to establish what proportion of data can be below the quantification limit without compromising NONMEM's parameter estimates. Using pharmacokinetic parameters determined in a rat toxicokinetic study we simulated datasets that might emerge from similar experiments in which only one sample was obtained per individual. A number of quantification limits were used which resulted in increasing proportions of data values being treated as if they were below the limit of quantification (BQL). For each quantification level we incorporated BQL data into our analyses in number of ways. We compared these analysis methods with respect to how well the underlying parameter values were retrieved. Omitting BQL data values or entering them as zero led to inaccurate and biased study results. We found that incorporating BQL values using more complex substitution methods via a mixed effects model produced more reliable and less biased parameter estimates. The four substitution methods that we investigated performed similarly. Parameter estimates became less reliable and more biased as the quantification level was increased depending on the method of BQL value incorporation. Naive methods of BQL data handling can produce unreliable and biased parameter estimates. An alternative is to incorporate BQL values into a population-type model, our results showed this method to be preferable. We found it advisable that the proportion of BQL data should not exceed one third and, if possible should be less than one quarter.
More Related Videos
05:47In Silico Modeling Method for Computational Aquatic Toxicology of Endocrine Disruptors: A Software-Based Approach Using QSAR Toolbox
Published on: August 28, 2019
10:03Quantification of Cytokine-Induced Cell Death in Human Colonic Organoids Using Live Fluorescence Microscopy
Published on: August 2, 2024
Related Concept Videos
Analysis of Population Pharmacokinetic Data
Analysis Methods of Pharmacokinetic Data: Model and Model-Independent Approaches
The model approach uses mathematical models to describe changes in drug concentration over time. Pharmacokinetic models help characterize drug behavior in patients, predict drug concentration in the body fluids, calculate optimum dosage regimens, and evaluate the risk of toxicity. However, ensuring that the model fits the experimental data accurately...
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This relationship...
Dose Response Curve: Conventional Versus Nonmonotonic
Toxicokinetics: Overview
Censoring Survival Data