A longitudinal study of the repeated use of alteplase as therapy for tunneled hemodialysis catheter dysfunction

Mark A Little1, J Joseph Walshe

  • 1Department of Nephrology and Transplantation, Beaumont Hospital, Dublin, Ireland.

When hemodialysis catheters allow only poor or no blood flow, it has become established practice in many centers to instill a thrombolytic agent in an attempt to clear the catheter. The catheter survival advantage gained by repeated use of such treatment is not known. In a prospective study, we analyzed all uses of alteplase in the setting of inadequate catheter blood flow in a cohort of 570 catheters over a 2(1/2)-year period. The time from alteplase instillation to the next episode in which it was required or catheter removal for nonfunction or thrombosis was recorded. Survival analysis was used to estimate the additional catheter survival afforded by each treatment. After censoring for elective catheter removal, the overall catheter half-life was 10.2 months. Catheter malfunction or thrombosis was the most common indication for catheter removal (36.3% of all catheters removed). Alteplase instillation was necessary in 2.77% of dialysis sessions. The median time from the first to second treatment or catheter removal for nonfunction or thrombosis was 27 days (95% confidence interval, 15.7 to 32.3). Additional median survival advantage gained from each subsequent treatment ranged from 10 to 18 days. Treatment of recurrent catheter malfunction with alteplase allows for a median of only five to seven additional dialysis sessions before the treatment must be repeated or the catheter must be exchanged. Although associated with minimal disruption to the dialysis schedule, the ultimate clinical benefit and cost-effectiveness of such treatment is doubtful.

Related Concept Videos

Continuous Renal Replacement Therapy01:30

Continuous Renal Replacement Therapy

Continuous Renal Replacement Therapy, also known as CRRT, is a procedural treatment for acute kidney injury (AKI) that gradually removes uremic toxins and fluids while maintaining acid-base balance and stabilizing electrolytes. It is particularly useful for hemodynamically unstable patients. Unlike intermittent hemodialysis, which is faster, CRRT provides a gentler approach over 24 hours, closely mimicking the function of natural kidneys. However, CRRT is not ideal for patients with...
Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
Venous Thrombosis III: Interprofessional Care01:29

Venous Thrombosis III: Interprofessional Care

Venous thrombosis requires effective prevention and treatment strategies to improve patient outcomes and reduce potential complications.Prevention StrategiesHealthcare providers must prioritize preventing venous thromboembolism (VTE) for all adult patients upon admission. Interventions depend on bleeding and thrombosis risk, medical history, current medications, diagnoses, planned procedures, and patient preferences. Patients on bed rest should change positions every two hours and, if not...