Related Experiment Video
Updated: Aug 10, 2026

Steps for the Autologous Ex vivo Perfused Porcine Liver-kidney Experiment
Published on: December 18, 2013
Acidosis correction with a new 25 mmol/l bicarbonate/15 mmol/l lactate peritoneal dialysis solution
A M Carrasco1, M A Rubio, J A Sanchez Tommero
1Hospital Clinico Universitario, Valencia, Spain.
Objective:
The aim of this study was to evaluate the effects of a combined 25 mmol/L bicarbonate/15 mmol/L lactate-based solution (Bic/Lac), compared to a 35 mmol/L lactate solution (Lac)--the most commonly used solution for patients in southern Europe--on the venous plasma bicarbonate level in patients treated with continuous ambulatory peritoneal dialysis (CAPD).
Design:
This was a randomized, parallel, controlled, open-label study, with patients studied for a period of 3 months preceded by a 1-month baseline and followed by a 1-month follow-up. Patients used the 35 mmol/L lactate solution during baseline and follow-up periods.
Setting:
Four Spanish nephrology centers.
Patients:
Thirty-one (20 Bic/Lac, 11 Lac) well-dialyzed (creatinine clearance > 55 L/week/1.73 m2 body surface area) CAPD patients.
Interventions:
Blood samples were taken for biochemistry tests at all visits. A physical examination was completed at baseline and month 3, and a medical update was completed after 1, 2, and 3 months, and at the follow-up visit. Adverse-event monitoring and notation of prescription changes were carried out continuously.
Main Outcome Measure:
Effect on venous plasma bicarbonate level.
Results:
Venous plasma bicarbonate rose by 3.1 mmol/L (confidence intervals 1.6-4.8),from a baseline level of 23.0 mmol/L during the treatment period in those patients treated with Bic/Lac (p < 0.05 vs Lac). The number of acidotic patients (venous plasma bicarbonate < 24 mmol/L) was statistically significantly reduced at every treatment period visit in the Bic/Lac group (p < 0.05). There were no adverse findings with respect to vital signs, physical examination, or clinical symptoms, apart from one death in the control group.
Conclusions:
The new Bic/Lac solution allowed better correction of acid-base status than the lactate solution.
Related Concept Videos
Acid-Base Balance
When the pH of arterial blood rises above 7.45, it results in a condition called alkalosis. Conversely, a drop below 7.35 leads to...
Bicarbonate-Carbonic Acid Buffer
Disorders of Acid-Base Balance
Respiratory Acidosis and Alkalosis
Respiratory acidosis occurs due to an increase in the partial pressure of carbon dioxide PCO2 in the blood. It often arises from shallow breathing or impaired gas exchange caused by...
Compensation Mechanisms
Respiratory Compensation
This mechanism addresses metabolic-induced pH imbalances by adjusting breathing rates. Respiratory compensation begins within minutes of detecting a pH...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Peritoneal Dialysis I: Introduction and Procedure