Differentiation of atrial rhythms from the electrocardiogram with coherence spectra
Related Experiment Video
Updated: Oct 3, 2026

High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
Lara S Sarraf1, James A Roth, Kristina M Ropella
1Department of Biomedical Engineering, Marquette University, Milwaukee, WI 53201, USA.
Abstract:
Automated electrocardiogram (ECG) interpretation systems fail to reliably discriminate atrial fibrillation from sinus rhythm and other more regular atrial arrhythmias. Previously, magnitude-squared coherence (MSC), a frequency domain measure of the linear phase relation between 2 signals, has been shown to be a reliable discriminator of fibrillatory and nonfibrillatory cardiac rhythms when applied to intracardiac electrograms. This study determines whether MSC, when applied to the surface electrocardiogram, would discriminate between atrial fibrillation and nonfibrillatory atrial rhythms. MSC was analyzed by using 2 surface leads of a 10-second ECG. For 68 ECG recordings (23 sinus rhythm, 22 atrial flutter, and 23 atrial fibrillation), MSC was computed between leads II and V1 and the mean MSC in several frequency bands was examined. The performance of MSC was compared to previously published measures of ventricular irregularity and percent power in discriminating atrial fibrillation from nonfibrillatory rhythms. As hypothesized, atrial fibrillation exhibited low coherence in the 2 to 9 Hz band while nonfibrillatory atrial rhythms exhibited relatively moderate to high levels of coherence in the same frequency band. Mean MSC in the 2 to 9 Hz band was significantly lower for atrial fibrillation (range, 0.04 to 0.48; mean +/- SD: 0.15 +/- 0.11) than for sinus rhythm (range, 0.18 to 0.81; 0.47 +/- 0.17) (P <.0005) and atrial flutter (range, 0.06 to 0.80; 0.44 +/- 0.21) (P <.0005). Mean MSC in the 2 to 9 Hz band showed less overlap between atrial fibrillation and atrial flutter than R-R variability and percent power. However, R-R variability showed less overlap between atrial fibrillation and sinus rhythm than mean MSC and percent power. Thus, MSC and RRV both discriminate atrial fibrillation from more organized atrial rhythms. Conversely, percent power was highly variable for both atrial fibrillation and organized atrial rhythms. Results suggest that MSC applied to surface ECG may be used to quantify rhythm organization.
More Related Videos
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Electrophysiology of Normal Cardiac Rhythm
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...