Unusual atrial response to electrical pacing during ischemia
Related Experiment Video
Updated: Oct 3, 2026

Optimization of Transesophageal Atrial Pacing to Assess Atrial Fibrillation Susceptibility in Mice
Published on: June 29, 2022
Tokuhisa Uejima1, Koichi Sagara, Takeshi Yamashita
1Cardiovascular Institute Hospital, Tokyo, Japan. t.uejima@nifty.ne.jp
Insights
A patient with unstable angina experienced prolonged atrial intervals during cardiac ischemia, alongside an unusual electrophysiological phenomenon where atrial capture occurred at 90 ppm but not 80 ppm.
Area of Science:
- Cardiology
- Electrophysiology
- Cardiac Surgery
Background:
- A 76-year-old woman with a dual chamber pacemaker presented with unstable angina requiring coronary intervention.
- Post-procedure, recurrent chest pain and reduced distal coronary flow necessitated emergent coronary artery bypass grafting.
Observation:
- During the ischemic events, a prolonged stimulation-excitation interval of the atrium was noted.
- An unusual electrophysiological phenomenon was observed: atrial capture at 90 beats per minute (bpm) but not at 80 bpm.
Findings:
- The atrial stimulation-excitation interval prolongation correlated with the severity of myocardial ischemia.
- The observed capture phenomenon suggests potential phase 4 depolarization or rate-dependent conduction facilitation in the ischemic atrium.
Implications:
- This case highlights a potential link between myocardial ischemia and altered atrial electrophysiology in pacemaker patients.
- Understanding such transient electrophysiological changes is crucial for managing cardiac patients, especially those with implanted devices.
- Further research may elucidate the mechanisms behind rate-dependent conduction abnormalities during acute ischemia.
Abstract:
A 76-year-old woman with a dual chamber pacemaker underwent coronary intervention of the right coronary artery for unstable angina. After the procedure, she had recurrent chest pain, and after the repeat angiography showed reduced coronary flow in the distal vessel, she underwent emergent coronary artery bypass grafting. During this course of events, the stimulation-excitation interval of the atrium was prolonged and paralleled with the severity of the ischemia. Additionally, a transient but unusual electrophysiological phenomenon was observed that the atrium could be captured at a rate of 90 ppm, but not 80 ppm. This phenomenon might be caused by phase 4 depolarization or rate-dependent facilitation of conduction in the ischemic atrium.
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Electrophysiology of Normal Cardiac Rhythm
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials