Related Experiment Video
Updated: Aug 1, 2026

Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
Nonlinear methods of biosignal analysis in assessing terbutaline-induced heart rate and blood pressure changes
Tom A Kuusela1, Tuomas T Jartti, Kari U O Tahvanainen
1Department of Physics, University of Turku, 20014 Turku, Finland. tom.kuusela@utu.fi
Abstract:
The aim of this study was to characterize how different nonlinear methods characterize heart rate and blood pressure dynamics in healthy subjects at rest. The randomized, placebo-controlled crossover study with intravenous terbutaline was designed to induce four different stationary states of cardiovascular regulation system. The R-R interval, systolic arterial blood pressure, and heart rate time series were analyzed with a set of methods including approximate entropy, sample entropy, Lempel-Ziv entropy, symbol dynamic entropy, cross-entropy, correlation dimension, fractal dimensions, and stationarity test. Results indicate that R-R interval and systolic arterial pressure subsystems are mutually connected but have different dynamic properties. In the drug-free state the subsystems share many common features. When the strength of the baroreflex feedback loop is modified with terbutaline, R-R interval and systolic blood pressure lose mutual synchrony and drift toward their inherent state of operation. In this state the R-R interval system is rather complex and irregular, but the blood pressure system is much simpler than in the drug-free state.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure

