A single center experience with the freestyle bioprosthesis: midterm results at the Québec Heart Institute
F Dagenais1, P Cartier, J G Dumesnil
1Department of Cardiothoracic Surgery, Québec Heart Institute-Laval Hospital, Québec City, Canada.
Abstract:
Stentless bioprostheses show excellent early hemodynamic performance. However, longevity still remains unknown. This study reports midterm follow-up in 419 patients in which a Freestyle bioprosthesis (Medtronic Heart Valves, Minneapolis, MN) was inserted between January 1993 and January 2000 at the Quebec Heart Institute (Ste-Foy, Québec, Canada). Mean age at implantation was 68.0 +/- 8.2 years. Implantation was subcoronary in 81.9% of the patients, as a root replacement in 16.5%, and as a root inclusion in 1.7%. Mortality at 30 days was 6.2% for the whole cohort (2.8% for isolated subcoronary aortic valve replacement). Female gender, root implantation, valve sizes 19 to 21 mm, previous surgery, a history of stroke and diabetes were identified as predictors of 30-day mortality. Actuarial freedom from all death causes was 81.5% at 7 years; freedom from valve-related deaths 97.0%, and freedom from cardiac deaths 92.7%. Freedom from thromboembolic events was 86.1% at 7 years (55.1% of events were < 30 days). Freedom from endocarditis and hemorrhagic complications were respectively 98.5% and 95.6% at 7 years. Six patients required reoperations for valve explantation: 2 for endocarditis, 2 for structural dysfunction, and 2 for nonstructural dysfunction. Incidence of moderate or severe valve insufficiency at annual echocardiographic follow-up was: discharge: 0.6%; year 1: 0.7%; year 2: 1.3%; year 3: 3.3%; year 4: 3.7%; year 5: 2.6%; year 6: 0%. At 6 years after implantation, mean transvalvular gradient and effective valve orifice area were comparable to the year 1 values. This single center experience with the Medtronic Freestyle prosthesis shows preserved hemodynamic performance and low valve-related complications at midterm.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Mitral Valve Prolapse II: Assessment and Management
Mitral Stenosis I: Introduction
Peripheral Artery Disease III: Interprofessional Care