Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
Published on: June 29, 2013
Waveforms of the ductus venosus blood flow in normal human fetuses aged 8-38 weeks
1Department of Obstetrics & Gynecology, Chang Gung Memorial Hospital, Niaosung, Taiwan, ROC. joanyeh@cgmh.org.tw
Background:
We attempted to establish normal Doppler flow velocity waveform patterns in the human fetal ductus venosus (DV), and also to establish a standardized measurement technique.
Methods:
Ductus venosus blood flow was measured in a prospective study involving 545 fetuses aged between 8 and 38 weeks in utero, the mothers of whom received prenatal care in Kaohsiung Chang Gung Memorial Hospital in a 12-month period in 1998-1999. Several DV hemodynamic parameters were assessed, including peak systolic velocity (DVP), peak systolic/diastolic (S/D) ratio, time-averaged velocity (TAMX), maximum velocity during atrial contraction (DVM), pulsatility index (PI), Pourcelot's resistance index (RI), and fetal heartbeat (FHB).
Results:
Technically acceptable ductus venosus blood flow velocity waveform patterns were collected from 490 of 545 pregnant women (89.9%). The mean +/- SD value for the peak systolic DV velocity during the time period of 8 to 38 weeks in utero was 0.33 +/- 0.11 meters/sec (m/s), the TAMX being 0.24 +/- 0.09 m/s. The maximum velocity during atrial contraction was 0.15 +/- 0.09 m/s, and the peak S/D velocity ratio was 2.5 +/- 1.01. The PI, Pourcelot's RI and fetal heart beat were, 0.67(+/- 0.21), 0.64 (+/- 0.11), and 163.3 (+/- 18.82 bpm), respectively. Significant increases in DVP, TAMX, and DVM with advancing gestational age were established, and decreases in PI, RI, S/D, and FHB with advancing gestational age were also observed.
Conclusions:
Further investigation of DV hemodynamics throughout pregnancy may enable a greater understanding of normal placental perfusion, the fetal venous return to the heart and associated cardiac function.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Development of the Heart
As the embryo undergoes lateral folding, these paired tubes approach each other, merging into a single primitive heart tube by...
Overview of Systemic Veins
The coronary sinus, the heart's principal vein, resides in the coronary sulcus on the heart's posterior aspect. This broad venous channel receives nearly all venous blood from the myocardium, the heart muscle. It is fed by three primary veins: the great cardiac vein, the middle...
Development of Blood Vessels
The initial formation of this system is facilitated by the small amount of yolk present in the ovum and yolk sac. Blood vessels originate from...
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...