Abstract:
The synthesis, characterization and biological evaluation of two novel 3 + 1 mixed ligand 99mTc-complexes, bearing the 1-(2-methoxyphenylpiperazine) moiety, a fragment of the true 5-HT1A antagonist WAY 100635, is reported. Complexes at tracer level 99mTcO[(CH3CH2)2NCH2CH2N(CH2CH2S)2][o-CH3OC6H4N(CH2CH2)2NCH2CH2S], 99mTc-1, and 99mTcO[((CH3)2CH)2NCH2CH2N(CH2CH2S)2][o-CH3OC6H4N (CH2CH2)2NCH2CH2S], 99mTc-2, were prepared using 99mTc-glucoheptonate as precursor. For structural characterization, the analogous oxorhenium complexes, Re-1 and Re-2, were prepared by ligand exchange reaction using ReOCl3(PPh3)2 as precursor, and characterized by elemental analysis and spectroscopic methods. Complex Re-1 was further characterized by crystallographic analysis. Labeling was performed with high yield (>85%) and radiochemical purity (>90%) using very low ligand concentration. The structure of 99mTc complexes was established by comparative HPLC using the well-characterized oxorhenium analogues as references. In vitro binding assays demonstrated the affinity of these complexes for 5-HT1A receptors (IC50 : 67 and 45 nM for Re-1 and Re-2 respectively). Biological studies in mice showed the ability of 99mTc-1 and 99mTc-2 complexes to cross the intact blood-brain barrier (1.4 and 0.9% dose/g, respectively at 1 min post-inj.). The distribution of these complexes in various regions in rat brain is inhomogeneous. The highest ratio between areas reach and poor in 5-HT1A receptors was calculated for complex Tc-1 at 60 min p.i. (hippocampus/cerebellum = 1.7).
More Related Videos
10:47Harnessing the Bioorthogonal Inverse Electron Demand Diels-Alder Cycloaddition for Pretargeted PET Imaging
Published on: February 3, 2015
13:21Preparation, Purification, and Characterization of Lanthanide Complexes for Use as Contrast Agents for Magnetic Resonance Imaging
Published on: July 21, 2011
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...