Mesopic contrast sensitivity function after excimer laser photorefractive keratectomy.

Robert Montés-Micó1, W Neil Charman

  • 1Unitat d'Optometria i Ciències de la Visió, Universitat de Valencia, Spain. roberto.montes@uv.es

Journal of Refractive Surgery (Thorofare, N.J. : 1995)
|February 7, 2002
PubMed
Summary

Photorefractive keratectomy (PRK) significantly reduces mesopic contrast sensitivity in myopia patients, even with normal photopic vision. This visual impairment occurs despite successful refractive correction.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Myopia control and modulation transfer functions for multisegment spectacle lenses.

Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)·2025
Same author

Oblique effects with multisegment spectacle lenses: 2. Ray tracing to determine power corrections.

Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)·2025
Same author

Oblique effects with multisegment spectacle lenses: 1. Images of a point object.

Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)·2025
Same author

Analysis of Crystalline Lens Tilt and Decentration Using a Fully Automated Swept-Source Optical Coherence Tomography Biometer.

Journal of refractive surgery (Thorofare, N.J. : 1995)·2025
Same author

Phoenix rising: Editing OPO, 1981-1987, volumes 1-7.

Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)·2025
Same author

Accuracy of intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in short and long eyes.

Frontiers in medicine·2024

Area of Science:

  • Ophthalmology
  • Vision Science

Background:

  • Myopia correction using excimer laser photorefractive keratectomy (PRK) is a common procedure.
  • Assessing visual function post-PRK, particularly contrast sensitivity under varying light conditions, is crucial for understanding visual outcomes.

Purpose of the Study:

  • To evaluate contrast sensitivity under mesopic conditions in patients who underwent uncomplicated PRK for myopia.
  • To compare mesopic and photopic contrast sensitivity in PRK patients versus a control group.

Main Methods:

  • Monocular contrast sensitivity was measured using the Stereo Optical F.A.C.T. chart in 26 PRK patients and 8 emmetropic controls.
  • Measurements were taken at four luminance levels (85, 5.0, 2.5, and 0.1 cd/m2) 6 months post-surgery.
  • Statistical analysis compared contrast sensitivity at various spatial frequencies between groups.

Related Experiment Videos

Main Results:

  • PRK patients showed a statistically significant reduction in contrast sensitivity under mesopic conditions (5.0, 2.5, 0.1 cd/m2) compared to controls (P < .01).
  • No significant differences in contrast sensitivity were observed between groups under photopic conditions (85 cd/m2) (P > .01).

Conclusions:

  • Excimer laser photorefractive keratectomy can lead to significant reductions in contrast sensitivity under mesopic conditions.
  • Photopic contrast sensitivity remains normal after PRK, indicating a specific impact on low-light vision.